6. Key specifications
Parameter |
Value |
Units |
---|---|---|
TDP running applications over 20 ms |
185 |
W |
Maximum pathological power consumption over 20 ms |
252 |
W |
Maximum idle power |
20 |
W |
Default power capping limit |
192 |
W |
Minimum power capping limit |
132 |
W |
Maximum power capping limit |
252 |
W |
Power capping resolution |
12 |
W |
Power capping accuracy |
5 |
% |
Power capping measurement time |
20 |
ms |
Maximum peak instantaneous current on 12 V supply |
30 |
A |
Peak instantaneous current measurement time |
1 |
ms |
Maximum inlet air temperature |
35 |
°C |
Maximum required airflow per card |
30 |
cubic feet/min |
850 |
litres/min |
|
SMBus register for fan control |
0x40 |
|
Fan control T(high) – increase fan speed |
65 |
°C |
Fan control T(low) – decrease fan speed |
50 |
°C |
IPU clock frequency under PWRBRK |
550 |
MHz |